Investigation of a tellurium-packed column for isolation of astatine-211 from irradiated bismuth targets and demonstration of a semi-automated system [electronic resource]

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả:

Ngôn ngữ: eng

Ký hiệu phân loại: 548.7 Mathematical crystallography

Thông tin xuất bản: Washington, D.C. : Oak Ridge, Tenn. : United States. Dept. of Energy. Office of Science ; Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 2019

Mô tả vật lý: Size: Article No. 16960 : , digital, PDF file.

Bộ sưu tập: Metadata

ID: 259941

 Astatine-211 is an attractive radionuclide for use in targeted alpha therapy of blood-borne diseases and micrometastatic diseases. Efficient isolation methods that can be adapted to robust automated <
 sup>
 211<
 /sup>
 At isolation systems are of high interest for improving the availability of <
 sup>
 211<
 /sup>
 At. Based on the early studies of Bochvarova and co-workers involving isolation of <
 sup>
 211<
 /sup>
 At from irradiated thorium targets, we developed a method for <
 sup>
 211<
 /sup>
 At isolation from bismuth targets using tellurium-packed columns. Dissolution of irradiated bismuth targets is accomplished using HNO<
 sub>
 3<
 /sub>

  however, <
 sup>
 211<
 /sup>
 At is not captured on the Te column material in this matrix. Our method involves slow addition of aqueous NH<
 sub>
 2<
 /sub>
 OH�HCl to the Bi target dissolved in HNO<
 sub>
 3<
 /sub>
  to convert to a HCl matrix. The amount of NH<
 sub>
 2<
 /sub>
 OH�HCl was optimized because (1) the quantity of NH<
 sub>
 2<
 /sub>
 OH�HCl used appears to affect the radiolabeling yield of phenethyl-<
 i>
 closo<
 /i>
 -decaborate(2-) (B10)-conjugated antibodies and (2) reducing the volume of NH<
 sub>
 2<
 /sub>
 OH�HCl solution can effectively shorten the overall isolation time. A proof-of-concept semi-automated process has been demonstrated using targets containing ~0.96 GBq (~26 mCi) of <
 sup>
 211<
 /sup>
 At. High isolation yields (88?95%) were obtained. Radiochemical purity of the isolated <
 sup>
 211<
 /sup>
 At was assessed by radio-HPLC. Concentrations of Bi and Te contaminants in the <
 sup>
 211<
 /sup>
 At and the astatinated antibodies were evaluated using ICP-MS.
Tạo bộ sưu tập với mã QR